Flint-walling CPJS Shallow Well Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
16
PUMP ELECTRICAL CONNECTIONS
3. Insert an electrical wire strain relief into the opening
in the side of the pressure switch closest to the motor.
(Fig. 3)
IL1372
3
IL1373
Wire from
motor
4
IL1374
Wire from
motor
5
IL1375
Wire from
motor
Ground Screws
6
6. Connect the green ground wire from the motor cable
to one of the green ground screws at the bottom of the
pressure switch. (Fig. 6)
5. Connect the two motor wires of the motor cable to the
two inside terminals on the pressure switch. (Fig. 5)
4. Thread the cable from the pump motor through the
strain relief into the pressure switch cavity and tighten
both screws on the strain relief. Do not crush wire.
(Fig. 4)
Vue de la page 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 22 23 24

Commentaires sur ces manuels

Pas de commentaire